Formlabs Fuse Sift 230V
- Home
- Shop
- Parts & Accessories, Formlabs Parts-Accessories
- Formlabs Fuse Sift 230V
Formlabs Fuse Sift 230V
Fuse Sift: All-in-one powder recovery station for Formlabs Fuse 1. Recycles 70% of used powder, automatically mixes fresh powder, removes unwanted particles.
- Description
Description
Formlabs Fuse Sift 230V – Efficient Powder
Recovery System Recover and reuse 3D printing powder
The Formlabs Fuse Sift 230V is an efficient, all-in-one powder recovery system designed to streamline material reuse in SLS 3D printing.
It provides a safe and clean method for recovering and recycling powder, enhancing workflow efficiency and reducing waste.
The Fuse Sift is a safe, efficient powder recovery system for the Fuse 1 generation printers. This easy-to-use, all-in-one station combines part extraction, powder recovery, storage, and mixing in a single free-standing device, for the most functionality in a single device available on the SLS market.
Compact, enclosed system: A negative air pressure system keeps powder inside while enabling open access and easy cleanup. With the optional Fuse Sift Glovebox Panel, you can completely contain powder and enable faster parts extraction.
Low waste: A 30% material refresh rate means you can print with up to 70% recycled powder, indefinitely. Fuse Sift’s sieve filters out particles to be remixed with new powder and reused in future prints.
Automatic powder mixing: Fuse Sift will dispense and mix used and new powder automatically so you can reduce waste and control your powder supply.
Nonstop printing: Reduce downtime by transferring modular build chambers and powder cartridges between the Formlabs SLS 3D printer and Fuse Sift for a nonstop, cyclical workflow.
A complete toolkit: The Fuse Sift includes a set of finishing tools to help you clean excess powder from parts with ease.
Printer compatibility: Fuse 1, Fuse 1+ 30W
Why Choose Fuse Sift
Fuse Sift streamlines your workflow with Fuse Series 3D printers by creating a seamless, contained environment for SLS production.
Mess-Free Post-Processing
Keep your workspace clean thanks to the negative air pressure system that keeps powder inside while enabling open access and easy cleanup.Automated Powder Mixing
Fuse Sift filters used powder and dispenses and mixes new powder automatically in a seamless workflow that lets you control your supply and reduce waste.Nonstop Printing
Reduce downtime by transferring modular build chambers and powder cartridges between the Formlabs SLS 3D printer and Fuse Sift for an uninterrupted, cyclical workflow.A Complete Toolkit
Fuse Sift includes a set of finishing tools to help you clean excess powder from parts with ease.
Fuse Sift Tech Specs
Fuse Sift | |
---|---|
Printer Compatibility | Fuse Series SLS 3D printers |
Dimensions (W x D x H) | 101.5 × 61.0 × 154.5 cm 39.9 × 24.0 × 60.8 in |
Height When Open | 190 cm (75 in) |
Fuse Sift Weight | 93 kg (without build chamber or powder) 205 lb (without build chamber or powder) |
Build Chamber Dimensions (W × D × H) | 27.9 × 34.2 × 48.9 cm 11.0 × 13.5 × 19.3 in |
Minimum Access Dimensions (W × D × H) | 221.1 × 122.0 × 218.0 cm 87.1 × 48.0 × 85.8 in |
Build Chamber Weight | 11 kg (17.6 kg, full with 20% packed powder) 24.3 lb (38.8 lb, full with 20% packed powder) |
Build Chamber Dimensions (W × D × H) | 27.9 × 34.2 × 48.9 cm 11.0 × 13.5 × 19.3 in |
Build Volume | 16.5 x 16.5 x 30.0 cm (with radiused corners) 6.5 × 6.5 × 11.8 in (with radiused corners) |
Fresh Powder Hopper Capacity | 17 liters |
Used Powder Hopper Capacity | 18 liters |
Operating Environment | 18 – 26 ºC 68 – 80 ºF ≤ 30% ambient humidity |
Air Handling | Negatively pressurized hood with replaceable HEPA filter Independent venting system |
Air Filtration | Replaceable HEPA medium |
Power Requirements (with a vacuum that draws less than 6 A (230 VAC) / 12 A (120 VAC)) | EU: 230 VAC, 7.5 A (dedicated circuit) US: 120 VAC, 15 A (dedicated circuit) |
Power Requirements (with a vacuum that draws more than 6 A (230 VAC) / 12 A (120 VAC)) | EU: 230 VAC, 10 A (dedicated circuit) US: 120 VAC, 20 A (dedicated circuit) |
Vacuum Requirements | Auxiliary vacuum with static dissipative components that is grounded and bonded (e.g., a NFPA 652 compliant vacuum) |
Connectivity | Wi-Fi (2.4 GHz) Ethernet (1000 Mbit) USB 2.0 |
Ethernet Connectivity | RJ-45 Ethernet (10BASE-T/100BASE-TX/1000BASE-T) LAN port Connect with a shielded Ethernet cable (not included): minimum Cat5, or Cat5e or Cat6 for 1000BASE-T. |
Wi-Fi Connectivity | Protocol: IEEE 802.11 b/g/n Frequency: 2.4 GHz Supported security: WPA/WPA2 |
USB Connectivity | USB (rev 2.0) B port with a USB A-B cable |
Sound Emission | Does not exceed 76.5 dB(A) |
Fuse Sift Control | Interactive touchscreen, physical buttons |
Included Accessories | Large Brush, Small Brush x 2 Pipe Cleaners Dental Picks Gloves Dust Mask Safety Glasses Vacuum Brush Tool Vacuum Crevice Tool Lifting Straps |
Optional Accessories | Fuse Sift Glovebox Panel Parts Carrier |